SSC Model Number
|
Linemaster® Hercules Model
|
Square D® Model Number |
Description/ Rating for SSC Models
|
Info Sheet/ Image |
|
G-Series Heavy-Duty Foot Switch |

download
info sheet
(276kb)
G-Series Foot Switch Home Page
|
|
G500-MO
|
531-SWH,
531-SWHO,
531-SWHOX
Hercules® |
9002AW2, 9002AW1,
9002AW12, 9002AW132 |
momentary, 20 amps @ 125/250 VAC (SPDT) |
|
G500-MA
|
571-DWH,
571-DWHO,
571-DWHOX |
9002AW12 |
maintained, 20 amps @ 125/250 VAC (SPDT) |
|
G500-AT
|
511-B,
511-BO,
511-BOX |
9002AW117 |
anti-trip, 20 amps @ 125/250 VAC (SPDT) |
|
G502-MO
|
532-SWH,
532-SWHO,
532-SWHOX |
9002AW14, 9002AW133, 9002AW13 |
momentary, two switches, single stage, 20 amps @ 125/250 VAC (SPDT) each
switch |
|
G502-MA
|
572-SWH,
572-SWHO,
572-SWHOX |
not applicable |
maintained, two switches, single stage, 20 amps @ 125/250 VAC (SPDT) each
switch |
|
G502-AT
|
511-B2,
511-B2O,
511-B2OX |
9002AW124 |
anti-trip, two switches, single stage, 20 amps @ 125/250 VAC (SPDT) each
switch |
|
G502-MO-2S
|
534-SWH,
534-SWHO,
534-SWHOX |
9002AW6 |
momentary, two switches, dual stage, 20 amps @ 125/250 VAC (SPDT) each
switch |
|
G502-AT-2S
|
511-B2A,
511-B2AO,
511-B2AOX |
9002AW119 |
anti-trip, two switches, dual stage, 20 amps @ 125/250 VAC (SPDT) each
switch |
|
G503-MO (three-switch models) |
533-SWH,
535-SWH,
etc. |
not applicable |
20 amps @ 125/250 VAC per switch |
|
G500-MO-DB (models with "double-break" switches) |
536-SWH, etc. |
not applicable |
contains switches with "double-break" circuitry;
add "-DB" to end of any SSC model number |
|
G500-MO-GT, G500-AT-GT, etc. (models with front gate) |
any gated model, such as Linemaster®
Hercules
511-BG (Anti-Trip with Gate) foot switch |
any gated model |
adds a front gate to the foot switch cover; add "-GT" to end of any SSC
model number |
|
GX500-MO (models with flat cover instead of guard) |
531-SWN
632-S |
not applicable |
available as a variation of all standard G-Series models; model
numbers begin with "GX" |
|
SSC Model Number
|
Linemaster® Model Number
|
Conntrol® Model Number |
Description/ Rating for SSC Models
|
Info Sheet/ Image |
|
S-Series Light-Duty Foot Switch |

download
info sheet (198kb)
S-Series Foot Switch Home Page
|
|
S100-1001 |
T-91-SC3
491-SC3
491-S
Linemaster® |
Conntrol®
Series 892
Series 862 |
10 amps @ 125 VAC, momentary (press and hold to keep on) |
|
S100-1002 |
T-91-SC36
491-SC36 |
Conntrol®
Series 892
Series 862 |
10 amps @ 125/250 VAC, momentary (press and hold to keep on) |
|
S100-1501 |
T-91-SC3A
971-S |
Conntrol®
Series 892
Series 862 |
15 amps @ 125 VAC, momentary (press and hold to keep on) |
|
S100-1502 |
T-91-SC36A
632-S |
Conntrol®
Series 892
Series 862 |
15 amps @ 125/250 VAC, momentary (press and hold to keep on) |
|
S420-1001 |
T-91-DC3
491-DC3A |
Conntrol®
Series 892
Series 862 |
10 amps @ 125 VAC, maintained (press to turn on, press again for off) |
|
S420-1002 |
T-91-DC36 |
Conntrol®
Series 892
Series 862 |
10 amps @ 125/250 VAC, maintained (press to turn on, press again for off) |
|
S420-1501 |
632-DA |
Conntrol®
Series 892
Series 862 |
15 amps @ 125 VAC, maintained (press to turn on, press again for off) |
|
S420-1502 |
632-DA |
Conntrol®
Series 892
Series 862 |
15 amps @ 125/250 VAC, maintained (press to turn on, press again for off) |
|
DS100 Dual Foot Switch |

download info sheet (309kb)
DS100 Foot Switch Home Page
|
|
DS100 and DS100-DG |
TWIN 971-SMC48
TWIN T-91-SC48
TWIN T-91-S
TWIN 491-S
TWIN HT-52-S
TWIN 632-S
TWIN 635-S
Linemaster® |
Conntrol®
Series 863 Dual
Series 893 Dual
Series 220
|
13 amps @ 125/250 VAC; each switch is wired normally open |
|
Potentiometer Foot Controls |

G700 info sheet (280kb)

L- and M-Series info sheet (206kb)
Potentiometer Foot
Controls Home Page
|
|
G700 and L- or M-Series Potentiometer Foot Control |
Linemaster® Hercules
Potentiometer Foot Control
500-H
500-H-xxxx
500-AH
500-N
500-N-xxxx
500-AN
500-HO
500-AHO
500-AHOX |
not applicable |
Available in potentiometer resistances of 1000, 5000, 10000, 25000, and
other common values. |
Note:
G-Series models with two switches can be
set so that both switches go off at the same time (DPDT circuitry) or
so that one switch activates before the other.
See the Foot Switch Selection Guide for more
information.