SSC Model
Number
|
Foot Control Description
|
Connector (View of Plug End Face)
|
Compatible
With:
|
|
C810-1425
|
TIG Foot Control for Miller® and Hobart® TIG
welders. Replaces Miller® RFCS-14 (p/n 043554), RFCS-14 HD
(p/n 194744), and Hobart®
p/n 043554-01-1.
|
14 pin
.jpg)
|
Works with any
Miller®
TIG welder equipped with a 14-pin remote connector.
Miller®:
Econotig;
AeroWave; ALT 304; Big Blue 302, Big Blue 402; CST 250; Dimension
302, Dimension 400, Dimension 452, Dimension 650, Dimension 652, Dimension
1000; Dynasty 200 SD and DX, Dynasty 300 SD; Dynasty 350; Dynasty 700;
Goldstar 300SS, Goldstar 400SS, Goldstar 500SS, Goldstar 600SS, Goldstar
302, Goldstar 452, Goldstar 652, Goldstar 402, Goldstar 602, Goldstar
852,
Maxstar 90, Maxstar 91, Maxstar
151, Maxstar 152, Maxstar 175,
Maxstar 200
SD, DX, LX, or STR, Maxstar 350,
Maxstar 700, Maxtron 300, Maxtron 450; Metro 250D, MK VI; Phoenix 456;
ShopMaster 300; SyncroWave 180, SyncroWave 200; SyncroWave 250; SyncroWave
350LX, SyncroWave 351, SyncroWave 500, SyncroWave 500P; TIG Runner;
Trailblazer 250G, Trailblazer 301G, Trailblazer 251NT, Trailblazer 300D
NT; XMT 200, XMT 300, XMT 304, XMT 350, XMT 456, 330 Aircrafter.
Miller® and
Hobart®
are registered trademarks of the Miller
Electric Mfg Co.
Hobart®:
TigMate, Cybertig 180, Cybertig 250, Cybertig 350
Powcon®: 300 TSE only, which has a metal
connection with a blue plastic center. All other PowCon see the
C880-1425 below.
|
|
C810-0525
|
TIG Foot Control for Miller®
TIG welders with 5-pin remote control connection. Replaces Miller® RFCS-5
(p/n 043716), RFCS-5 HD (p/n 195218). For RFCS-23, see info to the
right.
|
5 pin
.jpg)
|
Works with
Miller®
TIG welders equipped with a 5-pin remote connector.
Miller®:
Fits
all Miller® power sources prior to serial number
JK674521 that have a 5-pin remote receptacle.
Miller®:
Maxstar 150 (Not 150S, Not
150 STR or STH),
others not listed. Also works with the SynchroWave 300 (other
SynchroWaves use the 14-pin model above), which called out the RFCS-23.
If you have a different welder which wants the RFCS-23, please call
before buying so that we can check your owner's manual to verify.
Miller® and
Hobart®
are registered trademarks of the Miller
Electric Mfg Co.
|
|
C810-0625
|
TIG Foot Control for Miller® Maxstar 150 STL and STH.
Replaces Miller® RFCS-6M
(p/n 195183 and 195504).
|
6 pin
.jpg)
|
Miller®:
For Maxstar 150 STL and STH and Maxstar 140
STR with Lift Arc TIG option (current control only for the 140 STR TIG). Does not work with Maxstar 140, which
has no receptacle.
Hobart®:
Hobart 150 STi
|
|
C810-0814
|
TIG Foot Control for Miller® Dimension 165.
Replaces Miller® RFCS-RJ45 (p/n 300432).
|
8 pin RJ-45 Plug
.jpg)
|
Miller®:
For Diversion 165.
Note: This model is
our standard steel full-sized platform with million-cycle rating.
For some reason, Miller outsources this, so it's different than all of
their other pedals, using a steel top but plastic base and hinge pins.
|
|
C830-1425 |
TIG Foot Control for Snap-On® or Systematics® TIG250FP. |
14 pin
.jpg)
|
Snap-On® or Systematics®: TIG250H20, TIG250GAS |
|
C850-0825 |
TIG
Foot Control for Thermal Arc® welders. Replaces 10-4016, 10-4015, and
600285. |
8 pin
.jpg) |
Thermal Arc®:
For replacement of Thermal Arc foot controls with 8-pin connectors. |
|
C860-1430
|
TIG Foot Control for
ESAB® TIG welders. Replaces ESAB®
model FC-5B
(p/n 33646).
|
14 pin
.jpg)
|
ESAB®:
Miniarc
90i and 140i; Heliarc 252, Heliarc 352, Heliarc 582cc, Heliarc 453cc-553cc; Multimaster 260; Heliarc
160i; Miniarc 140i; Digipulse; Aristo 350 mpi, etc. |
|
C860-0625
|
TIG Foot Control for
ESAB®, Airco®, and Linde® TIG welders. Replaces
model FC-4
(p/n 13880043) or FC 004.
|
6 pin
.jpg)
|
ESAB®/ Airco®:
Heliwelder Works
with models which use the 6-pin rectangular connector. Note:
This
is not the same as the 2-plug version of the FC-4 (listed below).
Check the plug configuration of your welder. |
|
C870-0625 |
TIG Foot Control for Hobart® or L-TEC® welders with 6-pin
connector. Replaces Hobart foot control model 409213A. |
6 pin
.jpg) |
Hobart®: MegaArc with 6-pin
connector. L-TEC®:
MigMaster with TIG option and 6-pin.
|
|
C870-1025
|
TIG Foot Control for older Hobart® TIG welders. Replaces
Hobart®
models 409004A and 362668 and 200460-001.
|
10 pin
.jpg)
|
Hobart®: CyberTig; CT-200; CT-300; Cyberwave
300-S; Tigwave 250, TR250-HF, and others using the 10-pin connector.
|
|
C870-1225
|
TIG
Foot
Control for 12-pin Airco® TIG welders.
|
12 pin
.jpg) |
Airco®:
Heliwelder 251 AC/DC.
|
|
C880-1425
|
TIG Foot Control for 14-pin Powcon® TIG welders.
|
14 pin
.jpg)
|
Powcon®: Replaces remote TIG controls for Powcon
power sources using a 14-pin Amp®
twist-lock black plastic connector.
|
|
C890-0625
|
TIG
Foot
Control for Linde®
UCC-305
welder. Replaces Linde® FC-4 p/n 679662.
|
3 pin/3 pin
(two plugs)
.jpg) |
Linde®: UCC-305 and similar machines (uses two Hubbell®
Twist-Lock plugs).
L-TEC®: Heliarc 250 HF.
Note: This is
not the same as the 6-pin version of the FC-4 (listed above). Check
the plug configuration of your welder.
|
|
Models that use high-power rheostats that are not
compatible with the SSC design. |
|
SSC Model
|
Foot Control Description or Manufacturer's Model
|
Connector
|
Used
With:
|
|
----- |
Miller RFC-23A |
3 pin/2 pin (two plugs) |
Miller®: Dialarc 250 AC/DC, Dialarc HF, Gold Star 330 A/BP and 320
A/BP SSC does not make a pedal that replaces the RFC-23A, which uses a
15-ohm, 130-watt wire-wound resistor. Our design, like the design of
just about all the other welding pedals made today, uses 2-watt, higher
resolution rotary potentiometers for control. We suggest buying the
RFC-23A from your local Miller distributor. Do not confuse it with
the RFCS-23, RFC-23AG, or RFC-23GD25A, all of which are different models
and use 130W or 300W rheostats of different resistance values. |
|
---- |
Pedals for Hobart TG-201 and TG-301 |
5-pin |
Hobart models TG-201 and TG-301 use a 25-watt, 250-ohm rheostat and the
MS3106A18-20P 5-pin Amphenol plug (note: this information is not yet
verified). |
|
Note: The wattage is the maximum power that a
potentiometer or rheostat can handle (a rheostat is a high-power
potentiometer). In the 1960s and 1970s, welding manufacturers used
higher-wattage rheostats ranging from 25 to 250 watts, depending on the
model, but they changed to the safer circuitry associated with the 2-watt
potentiometer in the 1980s and have used this style since that time.
The SSC Controls foot pedals use a 2-watt potentiometer and cannot fit the
high-power rheostats. |
|
Other models that we cannot make: ESAB Migmaster 300i (foot control